A Day With A Lineman # 15 Getting Power to The Pumps

in #work7 years ago

It’s that time of year again, all the big farmers getting new and old pumps geared up for growing season.

Lets get some Poles in the Ground!

9D2024E1-924B-4250-80B0-B125081BD962.jpeg

Got the pole trailer loaded up with 5- 40 foot poles and 1- 45 foot pole. The 40 foot poles are for the line goin to the new pump and the 45 foot pole is the pole we will use to tap off the main line with to supple electricity to the new pump. That pole will be set between wires energized at 14,400 volts so that means a little…

Hot-sticking Today

After getting all the poles for the new tap to the new pump in the ground, we started working on getting the energized wires spread so we could get the new tap pole set between the 2 existing poles.

This requires a little Hot Work

5783E3E9-F4E0-40E4-A9FD-E19D14C69CAF.jpeg

Using specially designed fiberglass sticks with all kinds of different attachments, we untie the wire from the 2 adjacent poles and spread them out to our hot/spreader arms.

77396A9A-B412-4289-BBC6-013A3F79CE38.jpeg

Remind you these wires are still energized at 14,400 volts. So no customers lost power to their homes. Everything we use to handle the energized conductor is tested every year, and inspected before each use.

By spreading the wire, this creates a big “hole” where we can set the new pole between the energized conductors.

Just Sneak the Pole Right Up In There

0B2B15E3-767F-46B0-9DB0-282C795B62F8.jpeg

After the new tap pole is set, we go back to moving the wire back to the poles from our hot arms. While at the same time tieing them into our new pole.

23CA0D2C-35C0-47D0-A0EA-7893EB57C412.jpeg

INCOMING!

I was the one tieing the wire to the new pole. With these new insulators we just started getting it can be done with one person. They are pretty awesome. I will have to show you guys sometime.

After all that we strung in wire to the new pump and it was time to call it a day. A productive day it was.

These farmers will be very happy when these new pumps come online tomorrow.

Thanks for checking out another episode of…

A Day With A Lineman

Until next time

Steem on

33E0FA72-F641-44C5-B849-BAC505571EB3.gif

AND

46610A6A-15EE-4695-A212-3C1F08B20CD6.jpeg

Do Work

1A9CEB8D-B665-4B34-B977-EF6124E9BC08.gif

Sort:  

I had a customer a few months back tell me he worked in the vaults of all the major power plants and said you could touch a ground of high voltage and it would suck energy from you . He said your heart would stop after a few hours have you heard of this?

If you touch a grounded object to high voltage, uhhh ya it takes the energy out of you alright. Instantaneously your dead. 😉 Sound Like that guy needed to share whatever he was on. 😂😂

he said dudes have flashed there Soweto to the vaults wall . dude said there cant be listed as died because there is no body left. so there listed as missing

They can’t put together ashes😉 ya they got toasted. Some vaults have 230,000 volts in them, combines with thousands of amps… they gone!!

I used to work for Pacific Gas & Electric out of Fresno.

What a trip.

Electricity isn’t flat out mind blowing. I’m trying to get a guy at work to build a Tesla coil with me. I wanna shoot some lightning bolts. MUAHAHAHA

film it . what could go wrong ha ha